Examples of parameter setting – Yaskawa MP940 Reference Manual User Manual

Page 441

Advertising
background image

Position Control

MotionSuite™ MP940 Machine Controller Reference Manual

11-44

Setting examples of the parameters are shown in the table below:

Note: Select “enabled” (=1) in bit 9 “Override Selection” of fixed motion parameter 17.

Rated speed and number of feedback pulses per rotation are automatically
transmitted to the MP940 at power ON as data on the motor connected to
the SGDH.

Pulse counting mode selection: A/B format, fixed at quadrature

Examples of Parameter Setting

If the Speed Reference Selection is set to “0”

a.) When “pulses” is designated as the unit

When operating with fast feed speed = 1500rpm, approach speed =
300rpm, creep speed = 150rpm in the parameter settings

OWC00A = 300(rpm)×2048×4(ppr)÷1000 = 2457(=2457000ppm)

OWC00B = 150(rpm)×2048×4(ppr)÷1000 = 1228(=2457000ppm)

OWC015 = --- --- --- (disabled)

OLC022 = 1500(rpm)×2048×4(ppr)÷1000 = 12288(=12288000ppm)

OWC02C = 10000(100%)

b.) When “mm” is designated as the unit

Parameter Type

Parameter Number

(Register Number)

Name

Initial Value

Motion Setting
Parameters

Bit 13 of OWC001

Speed Reference Selection

0

OWC00A

Approach Selection

0

OWC00B

Creep Speed

0

OWC015

Speed Reference Setting

0

OLC022

Fast Feed Speed

0

OWC02C

Override

100%

Conditions
Pulse Calculation Format = A/B format (fixed at quadrature)
Rated Speed = 3000rpm
Motor Rotation Feedback Pulse = 2048P/R
Rated Speed = 3000
rpm = 3000×2048×4 = 2575000ppm
Setting examples for various parameters are shown below: