Yaskawa MP940 Reference Manual User Manual

Page 516

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

Parameters

A-29

24

Position Management
Status

IWC017

Bit 0: MLKL

Machine lock

Bit 1: ZERO

Zero-point position

Bit 2: PSET2

2nd INP completion

Bit 3: ABSLDE

ABS System Rotary Position Manage-
ment Data Load Completion

Bit 4: TPRSE

Number of POSMAX turns presetting
completion

Bit 5: GEARM

Copy of fixed parameter “Electronic
Gearing Selection”.

Bit 6: MODSELM

Copy of fixed parameter “Axis Selection”

Bits 7~11:

Unused

Bits 12~15:

Unused

25

Machine Coordinate
System Position

ILC018

-2

31

~2

31-1

1 = 1 command unit
Update will not occur in machine lock
when 1 = 1 pulse unit

27

SGDH Serial
Command Answer

IWC01A —

SGDH Serial Command Answer Monitor
Data Read
01H: Normal
41H: Data error
81H: Address error
Data Write
02H: Normal
42H: Data error
82H: Address error
C2H: Answer timeout

28

SGDH Serial
Command Address

ILC01B

Address monitor during SGDH serial
command execution

29

POSMAX Monitor

ILC01C

1~2

31-1

1 = 1 Command Units
Copy of fixed motion command “POS-
MAX”

31

POSMAX Number of
Turns

ILC01E

-2

31

~

231-1

1 = 1 Turn
The count goes UP/DOWN each time
POSMAX is exceeded. (initialized to 0 at
power ON)

33

SGDH Serial
Command Data

IWC020

Data monitor during SGDH serial com-
mand execution

Table 9: Monitor Parameters (Continued)

No.

Name

Register

Number

Bit Name

(Setting Range)

Meaning

Note