35

Servo Alarms

ILC022

Bit 0: SVERROR

Servo amplifier error

Bit 1: OTF

Positive overtravel

Bit 2: OTR

Negative overtravel

Bit 3: SOTF

Positive soft limit

Bit 4: SOTR

Negative soft limit

Bit 5:

Bit 6: TIMEOVER

Positioning time-out

Bit 7: DISTOVER

Excessive positioning distance

Bit 8:

Bit 9:

Bit 10: MODERR

Control mode error

Bit 11:
ZSET_NRDY

Zero-point not set

35

Servo Alarms

ILC022

Bit 12:

Bit 13:

Bit 14:

Bit 15:

Bit 16:

Bit 17: ABSOVER

Excessive absolute encoder rotation

Bit 18: PGLFLT

Encoder disconnection error

Bit 19:

Unused

Bits 20~31

Unused

37

Network Servo Alarm
Code

IWC024

-32768~32767

Currently occurring alarm code

38

Network Servo I/O
Monitor

IWC025

Bit 0: SIO

General-use input signal

Bit 1: DEC

Deceleration dogleg switch

Bit 2: P-OT

Forward limit switch input

Bit 3: N-OT

Reverse limit switch input

Bit 4: EXT1

External input signal 1

Bit 5: EXT2

External input signal 2

Bit 6: EXT3

External input signal 3

Bits 7~15:

Unused

39

Speed Reference
Output Value

ILC026

-2

31

~2

31-1

Enabled when speed reference selection
1 = 1 Command unit/H scan

41

Position Buffer Data

ILC028

-2

31

~2

31-1

Copies the position buffer data when the
motion command control flag BUF_R
(OBC021F) =1.

43

Unused

Table 9: Monitor Parameters (Continued)

No.

Name

Register

Number

Bit Name

(Setting Range)

Meaning