MotionSuite™ MP940 Machine Controller Reference Manual

Parameter Details

6-29

14

Linear
Deceleration
Time

OWC00D 0 ~ 32767

0

15

Positioning
Completed
Range

OWC00E 0 ~ 65535

Used in position control zero-point return
modes.
Sets the range in which the positioning
completion signal (bit 13 of IWC000) or
zero-point return completion signal (bit 15
of IWC000) turns ON.
Command Unit: See the description of bit
D of IWC000.

10

16

Following Error
Limit

OWC00F

0 ~ 65535

Used in the position, phase control, and
zero-point return modes.
Sets the limits outputting deviation error
(bit 0 of IWC000). Upon exceeding this
range, the deviation error goes ON, and
position control is executed using this
value as the deviation.
Deviation error is not detected if 0 is set.

65535

17

Position Loop
Gain

OWC010

0 ~ 32767

Parameter that sets up servo [Position
Loop Gain].
The [Position Loop Gain] is an important
constant that determines servo response
performance. The scale of the setting
value is shown as follows:

Set up the most suitable value according
to machine rigidity, inertia, servo motor,
etc.
• Setting range:1 ~ 32767 [0.1/s]

300
(30.0)

Other Command/Mode Settings (Continued)

Number

Name

Register

Number

Setting Range

Content

Default

Value

Speed (%)

NR

(100%)

NREF

0

NACC

NDEC

Time

(t)

Speed

Reference

40 ~ 250

Responsiveness is
extremely good (beware
of hunting!)

Normal Responsiveness

Advertising