Torque related constants (continued) – Yaskawa MP940 Reference Manual User Manual

Page 279

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

SGDH User Parameters

6-79

Pn403
Reverse Torque Limit

Pn404
Forward External
Torque
Limit

%
0 ~ 800

Used when applying a torque limit after mov-
ing the machine to a given position. (External
Torque Limit)
Using a contact input signal, enables the
torque (current) limit set beforehand in the
user parameters. Independent settings can
be made for both the forward and reverse
directions.

Input the external torque (current) limit for
both the forward and reverse directions.

100

Speed
Torque
Position

Torque Related Constants (Continued)

User

Parameter

Number

Digit

Position

Name

(setting

range)

Content

Default

Setting

Control

Mode

Torque

Torque Limit

Servo Amplifier

Reverse

Forward

P-CL

N-CL

Torque Limit

Torque Limit

Torque limit

Torque

Speed

Speed

Pn402 or Pn404
(the limit is
whichever one is
smaller)

Pn402

Pn403 or Pn405
(the limit is
whichever one is
smaller)

Pn403

Torque

Speed

Torque

Speed