SGDH User Parameters
MotionSuite™ MP940 Machine Controller Reference Manual
6-94
Note:
Output by OFF logic if a number of signals have been assigned to the same output circuit.
Signals not detected by the control mode are assumed to be OFF. For example, in speed control, the
/COIN signal is assumed to be off.
/WARN Signal Types: Overload, regen overload, optional warnings
Pn50F
(continued)
3
Warning
Signal Map-
ping (/
WARN)
0 ~ 3
As above
0:Unused Speed Torque
Position
Pn510 Output
Signal
Selections 3
0
NEAR Sig-
nal Mapping
(?NEAR)
0 ~ 3
As above
0: Unused Speed Torque
Position
1
Similar C
Signal Map-
ping (/C-
PULS)
0 ~ 3
As above
0: Unused
2
Unused
—
—
0
3
Unused
—
—
0
Pn512
output Signal
Reversal
Settings
0
SO1 (CN1-
25, 26)
Terminal
Output Sig-
nal Inversion
0
1
Not inverted
Inverted
0: Not
inverted
Speed Torque
Position
1
SO2 (SN1-
27, 28) Ter-
minal Output
Signal Inver-
sion
0
1
Not inverted
Inverted
0: Not
inverted
2
SO3(CN1-
29, 30)
Terminal
Output Sig-
nal Inversion
0
1
Not inverted
Inverted
0: Not
inverted
3
Unused
—
0
Sequence Related Parameters - Output Signal Selection (Continued)
User
Parameter
Number
Digit
Position
Name
Setting
Range
Content
Default
Settings
Control Mode