Input Signal Selection

A detailed list of sequence-related parameters appears below.

Sequence Related Parameters - Input Signal Selection

User

Parameter

Number

Digit

Position

Name

Setting

Range

Content

Default
Setting

Control

Mode

Pn50A Input
Signal
Selections 1

0

Input
Signal
Assignment
Mode

0

1

The assignment of the input

signals for sequencing is the
same as in the SGDB servo
amplifier.

The assignment of the above

input signal can be set as
desired.

1

Speed
Torque
Position

1

/SVON Sig-
nal Mapping
Set to 8 -
disabled

0

1

2

3

4

5

6

7
8
9

A

B

C

D

E

F

Enabled when the SI0 (CN1-40)

input signal is ON (L level).

Enabled when the SI1 (CN1-41)

input signal is ON (L level).

Enabled when the SI2 (CN1-42)

input signal is ON (L level).

Enabled when the SI3 (CN1-43)

input signal is ON (L level).

Enabled when the SI4 (CN1-44)

input signal is ON (L level).

Enabled when the SI5 (CN1-45)

input signal is ON (L level).

Enabled when the SI6 (CN1-46)

input signal is ON (L level).

The signal is always set to

enabled.

The signal is always set to

disabled.

Enabled when the SI0 (CN1-40)

input signal is OFF (H level).

Enabled when the SI1 (CN1-41)

input signal is OFF (H level).

Enabled when the SI2 (CN1-42)

input signal is OFF (H level).

Enabled when the SI3 (CN1-43)

input signal is OFF (H level).

Enabled when the SI4 (CN1-44)

input signal is OFF (H level).

Enabled when the SI5 (CN1-45)

input signal is OFF (H level).

Enabled when the SI6 (CN1-46)

input signal is OFF (H level).

8:disabled