Table 6: Monitor Modes
User
Parameter
Number
Display Content
Unit
Notes
Un000
Actual Motor Speed
rpm
—
Un001
Input Speed Reference
rpm
—
Un002
Internal Torque Reference
%
Percent of rated torque
Un003
Rotation Angle 1
Pulse
Number of pulses from 0
Un004
Rotation Angle 2
deg
Angle from zero point (electrical angle)
Un005
Input Signal Monitor
—
—
Un006
Output Signal Monitor
—
—
Un007
Input Reference Pulse Speed
rpm
—
Un008
Deviation Counter
Com-
mand
Unit
Position Deviation
Un009
Cumulative Load Factor
%
Value assuming 100% of rated torque
displays real torque at 10s intervals
Un00A
Regen Load Factor
%
Value assuming 100% processable
regen power
Displays regen consumption power in
10s intervals
Un00B
DB Resistor Consumption
Power
%
Value at 100% processable power dur-
ing dynamic brake operation
displays DB consumption current at 10s
interval
Un00C
Input Reference Pulse Counter
—
Displayed in hexadecimals
Un00D
Feedback Pulse Counter
—
Displayed in hexadecimals