Mechatrolink Function

MotionSuite™ MP940 Machine Controller Reference Manual

4-50

Pn50A.0~Pn50.B, Pn511

<R> User

Parameters

Name

Setting

Content

Factory

Setting

Set the following sequence input signal cir-
cuit assignments when using in connection
with the MP940.

Pn50A.0

1

The sequence input signal can be set as
desired.

0

Pn50A.167

/S-ON
Signal Mapping

8

The signal is fixed at “Disabled”
/S-ON uses signals on the global memory

0

Pn50A.2

/P-CON
Signal Mapping

8

The signal is fixed at “Disabled”
/P-ON uses signals on the global memory

1

Pn50A.3

/P-OT
Signal Mapping

2

Inputs the P-OT signal from the SI2 (CN1-
42) input terminal.

2

Pn50B.0

N-OT
Signal Mapping

3

Inputs the P-OT signal from the SI3 (CN1-
43) input terminal.

3

Pn50B.1

/ALM-RST
Signal Mapping

8

Signal is fixed at “disabled”

4

Pn50B.2

/P-CL
Signal Mapping

8

Signal is fixed at “disabled”

5

Pn50B.3

N-CL
Signal Mapping

8

Signal is fixed at “disabled”

6

Pn511.0

/DEC
Signal Mapping

1

Inputs the /DEC signal from the SI1 (CN1-
41) Input terminal.

8

Pn511.1

/EXT 1
Signal Mapping

4

Inputs the /EXT 1 signal from the SI4
(CN1-44) input terminal.

8

Pn511.2

/EXT 2
Signal Mapping

5

Inputs the /EXT 2 signal from the SI5
(CN1-45) input terminal.

8

Pn511.3

/EXT 3
Signal Mapping

6

Inputs the /EXT 3 signal from the SI6
(CN1-46) input terminal.

8

Disabled

/DEC

/P-OT

/N-OT

/EXT1

/EXT2

/EXT3

40 SI0

41 SI1

42 SI2

43 SI3

44 SI4

45 SI5

46 SI6

CN1