User Programs

MotionSuite™ MP940 Machine Controller Reference Manual

3-16

• Sub-sub-drawing

These are executed by reference from a sub-drawing using the SEE com-
mand.

• Operation Error Processing Drawing

These are automatically executed by the system program at operation error
generation.

• Functions

These are executed by referencing a source drawing, sub-drawing, or sub-
sub-drawing using an FSTART command.

• Motion Programs

These can only reference H drawings. They are executed by referencing a
source drawing, sub-drawing, or sub-sub-drawing using an MSEE command.

Types and Priority of Source Drawings

Source drawings are classified by their first letters (A, I, S, H, L) in
accordance with their processing objective. Priority and execution
conditions are determined as follows.

Types and Priority of Source Drawings

Type of

Source

Drawing

Drawing Role

Priority

Execution Conditions

Number of

Drawings

(Note)

DWG.A

Start Processing

1

Power Feed (executed once at
power ON)

4

DWG.I

Interrupt Processing

2

Generated by DI interrupt and
counter coincidence interrupt for
option modules executed by
external interrupt

8

DWG.S

System Scan

3

Set Interval Start (executed at each
servo control scan time)

16

DWG.H

High-speed Scan
Processing

4

Divides the servo control scan (S
scan) period into discrete time ele-
ments to execute the scan.

16

DWG.L

Low-speed Scan
Processing

5

Divides the servo control scan (S
scan) period into discrete time ele-
ments to execute the scan.

32