MotionSuite™ MP940 Machine Controller Reference Manual

System Errors

9-17

The latest data trace record number appears below.

User Operation Error Status - 4

Error

Code

Error Content

User

System Default

Integer/Real
Number
Operation

1000H

Index errors within drawing

Re-execute with i, j = 0

2000H

Index errors within function

Re-execute with i, ,j = 0

Integer
Operation

x060H
~
x077H
(x=1,2)

Integer-type System Functions
Index Error

Operation Hold and Output =
Input
The A register remains the
same

x06DH:PI

x06DH:PD

x06FH:PID

x070H:LAG

x071H:LLAG

x072H:FGN

x073H:IFGN

x074H:LAU

x075H:SLAU

x076H:FGN

x077H:IFGN

System Service Execution Status

Name

Register

Number

Reference

System Error Count

SW00090

System Error Codes

SW00091

Fault Occurrence Count

SW00092

Fault Recovery Count

SW00093

Reserved by System

SW00094 ~ SW00097 (Unused)

Existence of Data Trace Definition

SW00098

bit0 ~ 3 = Group1
Defined = 1; Undefined = 0

Data Trace Execution Status

SW00099

bit0 ~ 3 = Group 1
Trace Executing = 1; Trace Stopped = 0

Name

Register Number

Reference

Data Trace Group 1

SW00100

Latest Record Number