MotionSuite™ MP940 Machine Controller Reference Manual

Absolute Encoder Usage Method

7-21

Motion during power OFF is significant (phase position of encoder posi-
tion)

The meaning of the terms used is as follows:

- Encoder Position: Absolute Encoder Position Data

(Multi-turn Data × number of Encoder Pulses + Initial Incremental

Pulses)

- Pulse Position: Position at which position data managed by the

MP940 is converted to pulses.

Procedure for Setting a Zero-point for a Rotary Axis

Execute the ZSET (zero-point setting) for the motion command.

The system assures the pulse position at power OFF, encoder position at
power OFF, and all position data by the zero-point setting operation.

The operating procedure for zero-point setting in a rotary axis is shown
below:

Start

Servo ON

Move next to zero point

in JOG operation

Move to zero point in

STEP operation

Set desired position in

OLxx06

*1

Execute Zero Point

Setting

*2

End