MotionSuite™ MP940 Machine Controller Reference Manual

Absolute Encoder Usage Method

7-23

Configure the M register into which the above monitor parameters are
saved as follows:

Note:Two buffers are needed because the buffer saving the encoder position at power OFF and pulse posi-

tion at power OFF may close without assuring the 4-word position data if there is a power cutoff dur-
ing high-speed scan.

MWxxxxx

bit 0

Toggle Buffer Enable Flag (0 = enabled/1 = disabled)

bit 1

Toggle Buffer Selection Flag (0 = buffer 0/1 = buffer 1)

bit 2

Position Data Repeat Setup Request Flag (0 = complete/1 = Request)

MWxxxxx +1

Empty

MLxxxxx +2
MLxxxxx +4

Buffer 0

Monitor Parameter
“Encoder Position at Power OFF”

Lower 2 words (ILxx38)

Upper 2 words (ILxx3A)

MLxxxxx +6
MLxxxxx +8

Monitor Parameter
“Pulse Position at Power OFF”

Lower 2 words (ILxx3C)

Upper 2 words (ILxx3E)

MLxxxxx +10
MLxxxxx +12

Buffer 1

Monitor Parameter
“Encoder Position at Power OFF“

Lower 2 words (ILxx38)

Upper 2 words (ILxx3A)

MLxxxxx +14
MLxxxxx +16

Monitor Parameter
“Pulse Position at Power OFF”

Lower 2 words (ILxx3C)

Upper 2 words (ILxx3E)