System operation error status - 1 – Yaskawa MP940 Reference Manual User Manual

Page 347

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

System Errors

9-19

2. Mechatrolink Station Error Status For Slot 6

System Operation Error Status

(bit number)

F

E

D

9

8

1

0

SW00224

Unused

ST#14

ST#13

ST#1

Unused

SW00225

Unused

Unused

SW00226

Unused

Unused

SW00227

Unused

Unused

System Operation Error Status - 1

Name

Register

Number

Reference

Error Count

SW00600

Messaged when an operation error occurs
in a system program

Error Code

SW00601

Error A Register

SW00602

SW00603

Modification A Register

SW00604

SW00605

Error F Register

SW00606

SW00607

Modification F Register

SW00608

SW00609

Error IP

SW00610

Error CS

SW00611

Error Drawing Number

SW00612

Function Reference Drawing Number

SW00613

Function Reference Drawing Step Number SW00614

Reserved by System

SW00615

(Unused)