Position Control

MotionSuite™ MP940 Machine Controller Reference Manual

11-36

The parameters related to the position reference are shown in the table
below.

*1

Disabled when the position reference selection is “position buffer” (indirect designation).

*2

The setting data differs according to the position reference selection (bit 12 of OBC001)
and the position reference type (bit 14 of OBC001).

1. In indirect designation, in which the number of the position buffer is

designated, the position stored in the position buffer is handled as an
absolute position.

The position reference set in OLC012 is handled as an absolute posi-
tion when no motion command (OWC020) is used.

2. Set bit 14 of OWC001 “Position Reference Type” to the incremental

addition format when a motion program is used.

The system does not operate normally if a motion program is executed
in the absolute position format.

Parameter Type

Parameter Number

(Register Number)

Name

Content

Initial

Value

Motion Setting
Parameters

Bit 12 of OWC001

Position
Reference
Selection

Sets the position reference designation
method.
0: Direct Designation

Direct setting of position data into
OLC012. Designate whether the
position data is in absolute position
format or incremental addition for-
mat in bit 14 of OWC001.

1: Indirect Designation

Set the position buffer number into
OLC012. The absolute position
must be stored beforehand into the
designated position buffer.

0

Bit 14 of OWC001

Position
Reference Type

Designates position data type.
0: Absolute Position Format

Sets the absolute position in
OLC012.

1: Integral Addition Format

Sets the previous value of OLC012
to which the current motion amount
has been added into OLC012.*1

1

OLC012

Position
Reference
Setting

Sets position data.*2

0