MotionSuite™ MP940 Machine Controller Reference Manual

Parameter Outline

6-1

Chapter 6: Parameters

The parameter setting methods (which are needed for the MP940 system operation) are
explained in this chapter.

Parameter Outline

This section describes the parameter outline which is needed for the MP940 motion
modules. Read this thoroughly for a complete understanding of the parameters.

Parameter Types and Classifications

The parameters are the “specified constants” which are needed for the
motion function of the MP910 modules. Set up the most suitable
parameter values so that the performance of the applied servo drives (

=

motor + amplifier) corresponds to machine specifications. To create or edit

the parameters, use the MotionWorks

TM

Programing Unit.

Parameters are classified into the following four types:

Parameter Types

Classification

Register

Number

Setting Contents

Fixed Parameters No Register

Sets up mechanical condition of machine, motor, encoder, etc.
These cannot be changed during operation because they can-
not normally be changed once set.

Setup
Parameters

OWC000 ~ OWC03F

Used for commanding the servo controller.They can be set up
from the motion program or ladder program while running.

Monitor
Parameters

IWC000 ~ IWC03F

User constants of the servo amplifier. They can be set up in the
Motion Parameter window.

Servo Amplifier
Parameters

Pn000 ~ Pn602

These are servo amplifier user parameters. They are set in the
motion parameter setup screen.