background image

MotionSuite™ MP940 Machine Controller Reference Manual

CNTR Function

4-27

Pulse Calculation Format

The following formats can be selected by setting fixed parameter 5 (Pulse
Calculation Method).

Pulse calculation format

• Sign Format

Positive logic 5V during differential input
UP count in A pulse input when B pulse input is LOW. DOWN
count in A pulse input when B pulse input is HIGH.

Negative logic 5V during differential input
DOWN count in B pulse input when A pulse input is HIGH. UP
count in B pulse input when A pulse input is LOW.

• A/B format

Positive Logic/Negative Logic
UP count by the A pulse input phase delay according to the B pulse
input. DOWN count by the A pulse input phase progress according
to the B pulse input.

• UP/DOWN format

Positive Logic/Negative Logic
The pulse input is the addition pulse. The B pulse input is the sub-
traction pulse.

Table 1: Pulse Calculation Format Type

Measurement Type

Pulse Calculation

Format *1

Multiple *2

Note

Reversible Counter

Sign Format

×1

×2

A/B format

×1
×2
×4

UP/DOWN format

×1
×2

A pulse

B pulse