MotionSuite™ MP940 Machine Controller Reference Manual

Zero-point Return (ZRET)

11-67

Operation when the transition signal (deceleration LS) is in the low
range at zero-point return operation start

1. Moves in a reverse direction at approach speed.

2. Decelerates at the upward transfer of the transition (deceleration LS)

signal.

3. Moves in a forward direction at approach speed.

4. After detecting the downward transfer of the transition pulse (decelera-

tion LS), the axis moves from the initial zero-point signal by the final
zero-point return run distance (OLC02A) at the upward transfer of the
pulse transition, stops, then assumes that position as the machine coor-
dinate zero-point.

DEC1+LMT+C-phase Pulse Format

Executes zero-point return using a limit switch (deceleration LS), a zero-
point return limit signal, and a zero-point signal (c-phase pulse) after fast
feed by linear accel/decel.(with a transition band)

Limit switches (deceleration LS) and zero-point return limit signals are
used in the following machine configurations.

Speed

Reference

0

Reverse Forward

Zero

Point

Creep Speed

Approach Speed

Dog-leg

(Deceleration LS)

Zero-point Signal

(C-phase Pulse)

Time

3.

2.

1.

4.

Zero Point

Return

Position

Zero Return Final Run

Distance