MotionSuite™ MP940 Machine Controller Reference Manual

User Parameter List

A-6

*1

The multi-turn limit is only enabled when the absolute encoder usage method Pn002.2 is set to “2”.
The limit is processed as 65535 under any other setting, even if the multi-turn limit setting data is
changed.

The multi-turn limit need not be changed except for special applications. Careless modification of

this data is dangerous.

*2

The setting in user parameter Pn111 is enabled when the setting of user parameter Pn110.1 is “0”.

*3

When this user parameter has been changed, the main and control power must be turned OFF and
then ON again (re-feed main power) in order to enable the function.

*4

This is normally set to zero. Set the regenerative resistor capacity (W) if an external regenerative
resistor is used.

S

equ

enc

e-

rel

ated

Pa

ra

met

er

s

Pn500

Positioning Completed Width

Command
Unit

0

250

7

Pn501

Zero Clamp Level

rpm

0

10000

10

Pn502

Rotation Detection Level

rpm

1

10000

20

Pn503

Speed Coincidence Signal Output
Width

rpm

0

100

10

Pn504

Near Signal Width

Command
Unit

1

250

7

Pn505

Overflow Level

256 com-
mand units

1

32767

1024

Pn506

Brake Reference — Servo OFF
Delay Time

10ms

0

50

0

Pn507

Brake Reference Output
Speed Level

rpm

0

10000

100

Pn508

Timing for Brake Reference during
Motor Operation

10ms

10

100

50

Pn509

Momentary Hold Time

ms

20

1000

20

Pn50A

Input Signal Selection 1

*3

2100

Pn50B

Input Signal Selection 2

*3

6543

Pn50C

Input Signal Selection 3

*3

8888

Pn50D

Input Signal Selection 4

*3

8888

Pn50E

Output Signal Selection 1

*3

3211

Pn50F

Output Signal Selection 2

*3

0000

Pn510

Output Signal Selection 3

*3

0000

Pn511

Input Signal Selection 5

*3

Pn512

Output Signal Reversal Setting

0

O

ther

Pa

ra

met

er

s

Pn600

Regenerative Resistor Capacity

*4

10W

0

1000

0

Pn601

Reserved Constant
(do not adjust)

0

1000

0

Table 1: User Parameters (Continued)

Type

User

Parameter

Number

Name

Unit

Lower

Limit

Upper

Limit

Factory
Setting