Motion parameter alarm (ilxx22) – Yaskawa MP940 Reference Manual User Manual

Page 353

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

Motion Error

9-25

Content of Motion Parameter Alarm (ILxx22)

The detailed content of the axis alarm flag (ILxx22) is shown below.

Motion Parameter Alarm (ILxx22)

Parameter Number

Content

b0:

Unused

b1: OTF

Positive Overtravel
Servo amplifier has detected positive overtravel (P-OT signal is ON)

b2: OTR

Negative Overtravel
Servo amplifier has detected negative overtravel (N-OT signal is ON)

b3: SOTF

Positive Soft Limit
Detects motion into the positive soft limit field

b4: SOTR

Negative Soft Limit
Detects motion into the negative soft limit field

b5:

Unused

b6: TIMEOVER

Positioning Timeout
Positioning was not completed within the time set in OWxx34 “Positioning
Completion Check Time” following feed completion.

b7: DISTOVER

Excessive positioning distance
A motion command was executed in which the positioning motion
exceeded the limit value.

b8:

Unused

b9:

Unused

b10: MODERR

Control Mode Error
A position control mode motion command was used outside of the position
control mode.

b11: ZSET_NRDY

Zero-point not set
Motion was designated while using an absolute encoder with no zero-point
set.

b12:

Unused

b13:

Unused

b14:

Unused

b15:

Unused

b16:

Unused

b17:

Excessive Absolute Encoder Rotation
The rotation of the absolute encoder has exceeded the range that can be
handled by the MP940.

b18: PGLEFT

Encoder Cutoff
Encoder cutoff was detected upon selection of the A/B pulse calculation
formula.

b19~b31:

Empty

Advertising