Command unit – Yaskawa MP940 Reference Manual User Manual

Page 427

Advertising
background image

Position Control

MotionSuite™ MP940 Machine Controller Reference Manual

11-30

The following table shows the different conditions under which motion
commands (OWC020) are used or not used.

The meanings and usage of the terms in the above table are shown below.

Command Unit

The command units input to this module depend on the following fixed
motion parameter settings.

Command units can be in pulses, millimeters, degrees, or inches.
Designate the command unit in bits 0 ~ 3 of fixed motion parameter 17
“Motion Control Function Selection Flag”.

The minimum command unit that can be designated in this module is set
in the above unit setting, or in fixed motion parameter 18 “Number of
Digits Below Decimal Point”. Refer to the table below.

Pulse units are used if motion commands (OWC020) are not used.

Item

When Motion Command

(OWC020) Is Not Used

When Motion Command

(OWC020) Is Used

Command Unit

Pulses

Any of the following can be
selected: pulse/mm/inch/deg

Electronic Gearing Function

Not possible

Possible

Linear Position Control

Possible

Possible

Rotary positioning control in one direction
only without reset after one rotation

Possible

Possible

Rotary position control with resetting after
one rotation

Not possible

Possible

Position Reference

Absolute Position Format

Either Absolute Position
Form at Incremental Calcula-
tion Format can be selected

Position Buffer

Not possible

Possible

Position Monitor

Pulse Unit

Command Unit

Speed Reference

% Command

Either % Command/Com-
mand Unit can be selected

Advertising