Reversible counter mode – Yaskawa MP940 Reference Manual User Manual

Page 122

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

CNTR Function

4-31

Reversible Counter Mode

This is the mode in which UP or DOWN counts are executed according to the
A/B pulse input.

The following functions are possible by output register designation in the
reversable counter mode.

• Attribute Prohibition :

Prohibits counter attributes.

• Attribute Presetting :

Forcibly changes the counter values.

• PI Latch Detection :

Places the counter value in memory when an external signal is input.

• Conformance Detection :

Outputs an external output signal when the output register conformance
detection setting value and the current counter value coincide.

*1.

Current Attribute Value = Hardware Counter (ILxxxx+4)

*2.

Attribute Pre-setting = Attribute Pre-setting Data (OLxxxx+2)

n1

n2

n3

n4

n5

n6

n7

n1

n2

n3

n4

n5

n6

n7

MIN
(80000000H)

MIN
(80000000H)

UP

Stop

UP

DOWN

UP

DOWN

DOWN

Ts

Current

Attribute *1

A, B Pulse

0

(+)

(-)

Attribute Preset *2

Ts :Scan Setting

MAX (7FFFFFFFH)

MAX (7FFFFFFFH)

Attribute Preset *2

C

ounter A

ttri
bute R

egi

ster

Stop

Stop

Advertising