MotionSuite™ MP940 Machine Controller Reference Manual

Control Mode

11-25

2. Turning the zero-point return mode (ZRN) (Bit 4 of OWC000) ON.

3. Zero-point Return Run Start

a.) Turn the RUN command ON (Bit 0 of OWC001). The axis moves in

the direction specified in “Zero-point Return Direction Selection”
(ZRNDIR) (Bit 9 of OWC000).

b.) The axis decelerates to creep speed when the “Zero-point Return

Deceleration Point Limit Switch” (LSDEC) (Bit 15 of OWC001) goes
ON.

Name

Register

Number

Setting Range

Meaning

Setting

Example

Forward Torque Limit
(TLIMP)

OWC002

-327.68 ~ 327.67

0.01 = 0.01
%1 = 1%

-100.00
(-100.00%)

Positive Speed Limiter
(NLIMP)

OWC004

0.00 ~ 327.67%

0.01 = 0.01
%1 = 1%

130.00
(130.00%)

Negative Speed Limiter
(NLIMN)

OWC005

0.00 ~ 327.67%

0.01 = 0.01
%1 = 1%

130.00
(130.00%)

Zero-point Position Offset
(ABSOFF)

OLC006

-2

3

1

~ 2

31-1

1 = 1 command unit
During pulse 1 = 1 pulse

100 pulses

Approach Speed Setting
(NAPR)

OWC00A

0 ~ 32767

% of Rated Speed 1 =
0.01%

2000
(20.00%)

Creep Speed Setting
(NCLP)

OWC00B

0 ~ 32767

% of Rated Speed 1 =
0.01%

1000
(10.00%)

Linear Acceleration Time
(NACC)

OWC00C

0 ~ 32767

Linear acceleration time
constant at speed
parameter generation
(ms)

1000
(1s)

Linear Deceleration Time
(NDEC)

OWC00D

0 ~ 32767

Linear deceleration time
constant at speed
parameter generation
(ms)

1000
(1s)

Positioning Completion Range
Setting
(PEXT)

OWC00E

0 ~ 65535

1 = 1 command unit
During pulse 1 = 1 pulse

10 pulses

Deviation Error Detection Setting
(EOV)

OWC00F

0 ~ 32767

1 = 1 command unit
During pulse 1 = 1 pulse

65535 pulses

Position Loop Gain Setting
(KP)

OWC010

0.0 ~ 3276.7

0.1 = 0.1 /s
1 = 1 /s

30.0
(30.0 /s)

Filter Time Constant
(NNUM)

OWC014

0 ~ 255

For simple S-curve
accel/decel

0