background image

MotionSuite™ MP940 Machine Controller Reference Manual

Mechatrolink Function

4-45

Pn004.0

Option Board Selection

1

Option Board-compatible

Automatically set to “1” at
power ON

Pn005.0

Brake Control Function
Selection

0

Brake Control by Servo

Pn50A.0

I/O Assignment Mode

1

Signals may be assigned
freely

Pn50A.1

/S-ON Signal Mapping

8

Disabled

/S-ON uses the signals on
the global memory.

Pn50A.2

/P-CON Signal Mapping

8

Disabled

/P-CON uses the signals on
the global memory.

Pn50A.3

/P-OT Signal Mapping

2

Assigned to SI2(CN1-43)

Pn50B.0

N-OT Signal Mapping

3

Assigned to SI3(CN1-43)

Pn50B.1

/ALM-RST Signal Map-
ping

8

Disabled

/ALM-RST uses the signals
on the global memory.

Pn50B.2

/P-CL Signal Mapping

8

Disabled

/P-CL uses the signals on
the global memory.

Pn50B.3

/N-CL Signal Mapping

8

Disabled

/N-CL uses the signals on
the global memory.

Pn50C.0

/SPD-D Signal Mapping

8

Disabled

Pn50C.1

/SPD-A Signal Mapping

8

Disabled

Pn50C.2

/SPD-B Signal Mapping

8

Disabled

Pn50C.3

/C-SEL Signal Mapping

8

Disabled

/C-SEL uses the signals on
the global memory.

Pn50D.0

/ZCLAMP Signal Map-
ping

8

Disabled

/Z-CLAMP uses the signals
on the global memory.

Pn50D.1

/INHIBIT Signal Map-
ping

8

Disabled

Pn50D.2

/G-SEL Signal Mapping

8

Disabled

/G-SEL uses the signals on
the global memory.

Pn511.0

/DEC Signal Mapping

1

Assigned to SI1(CN1-41)

Enabled in “L”

Pn511.1

/EXT1 Signal Mapping

4

Assigned to SI4(CN1-44)

Enabled in “L”

Pn511.2

/EXT2 Signal Mapping

5

Assigned to SI5(CN1-45)

Enabled in “L”

Pn511.3

/EXT3 Signal Mapping

6

Assigned to SI6(CN1-46)

Enabled in “L”

SGDH User Parameter Settings (Continued)

Parameter

Number

Name

Setting

Setting Content

Reference