MotionSuite™ MP940 Machine Controller Reference Manual

Input Signal Selection List

A-13

Only Pn50A.1 = 7, Pn50A.3 = 8, and Pn50B.0 = 8 can be set in the SGDB servo amplifier function conver-

sion mode where Pn50A.0 = 0.

Pn50B
Input
Signal
Selection

0

N-OT Signal Mapping
(Overtravel at H)

0~F

As above

3: SI3

1

/ALM-RST Signal Map-
ping
(alarm reset at L)

0~F

As above

4: SI4

2

/P-CL Signal Mapping
(torque limit at L)

0~F

As above

5: SI5

3

/N-CL Signal Mapping
(torque limit at L)

0~F

As above

6: SI6

Pn50C
Input
Signal
Selection

0

/SPD-D Signal Mapping
(internal setting speed
selection)

0~F

As above

8: Dis-
abled

1

/SPD-A Signal Mapping
(internal setting speed
selection)

0~F

As above

8: Dis-
abled

2

/SPD-B Signal Mapping
(internal setting speed
selection)

0~F

As above

8: Dis-
abled

3

/C-SEL Signal Mapping
(control mode switching)

0~F

As above

8: Dis-
abled

Pn50D
Input
Signal
Selection

0

/ZCLAMP Signal Mapping
(zero clamp)

0~F

As above

8: Dis-
abled

1

/INHIBIT Signal Mapping
(command pulse inhibi-
tion)

0~F

As above

8: Dis-
abled

2

/G-SEL Signal Mapping
(gain switching)

0~F

As above

8: Dis-
abled

3

(reserved)

0~F

As above

8: Dis-
abled

Pn511
Input
Signal
Selection

0

/DEC Signal Mapping
(DEC when ON (L))

0~F

As above

8: Dis-
abled

1

/EXT Signal Mapping
(external latch when ON
(L))

0~F

As above

8: Dis-
abled

2

/EXT Signal Mapping
(external latch when ON
(L))

0~F

As above

8: Dis-
abled

3

/EXT Signal Mapping
(external latch when ON
(L))

0~F

As above

8: Dis-
abled

Table 3: Input Signal Selection (Continued)

User

Parameter

Number

Decimal

Place

Name

Setting

Content

Factory

Setting