Yaskawa MP940 Reference Manual User Manual
Page 113
Advertising
LI/O Function
MotionSuite™ MP940 Machine Controller Reference Manual
4-22
*
The linearity of the analog output is guaranteed only within the range of +/-10.0V.
Analog
Output Circuit
Register No.
OW0001 (default) Setting is possible in the Module Configuration
Definition Screen.
Item
Content
47Ω
1kΩ
-
+
+15V
-15V
1
26
L
-10~+10V
External Device
P