Absolute Encoder Usage Method

MotionSuite™ MP940 Machine Controller Reference Manual

7-18

Example: When Setting the Current Machine Coordinate Position to “0”
during Zero-point Setting Execution:

Set 0 into OLxx06

Procedure for Setting a Zero-point for a Linear Axis

After executing absolute encoder initialization, set the machine coordinate
zero-point and create the machine coordinate system by executing zero-point
setting.

The operating procedure for executing zero-point setting in a linear axis is
shown below:

*1

The OLxx06 value must be saved at the same time as setting OLxx6.

*2

See the following supplemental item on saving OLxx06.

*3

Execute with the ZSET command.

Start

Servo ON

Move to zero point in

STEP operation

OLxx06=-(ILxx02)+OLxx06

∗1

Preserve OLxx06

*2

End

Move next to zero point

in JOG operation

Execute Zero

Point Setting

*3