Troubleshooting

MotionSuite™ MP940 Machine Controller Reference Manual

10-42

Alarm Display List

The ON/OFF relationship between the “Alarm Display” and the “Alarm
Code Output” is shown in the table below:

Alarm Display and Alarm Code Output Relationship

Alarm

Display

Alarm Code Output

ALO1

ALO2

ALO3

Servo
Alarm

(ALM)

Output

Alarm Name

Alarm Content

A.02

x

Parameter
Breakdown*2

Servo amplifier
EEPROM data error

A.03

—

—

—

—

Main Circuit Detector
Error

Some power circuit
detection data is corrupt.

A.04

—

—

—

—

Parameter Setting
Error*2

A user parameter value
has been set outside the
setting range.

A.05

—

—

—

—

Mismatch Error

The capacities of the
motor and amplifier do
not match.

A.10

Overcurrent or Heat
Sink Overheat*2

Excessive current has
flowed to the IGBT, or
the servo amplifier heat
sink has overheated.

A.30

Regen Error

Regen Resistor
Disconnection
Regen Transistor Fault

A.32

—

—

—

—

Regen Overload

The regen energy
exceeds the capacity of
the regen resistor.

A.40

x

Overvoltage

The main circuit DC volt-
age is extremely high.

A.41

—

—

—

—

Undervoltage

The main circuit DC volt-
age is too low.

A.51

Overspeed

Servo motor speed is
extremely high.

A.71

Overload (Momentary
Maximum Load)

Motor has run for several
seconds or tens of sec-
onds at a torque greatly
exceeding the rated
value.

A.72

—

—

—

—

Overload (Continuous
Maximum Load)

The servo motor has
operated continuously at
a torque exceeding the
rated value.