Mechatrolink Function

MotionSuite™ MP940 Machine Controller Reference Manual

4-38

Mechatrolink Connection

The following shows the conneciton of the MP940 module to an IO350 unit.
Use the standard cable (JEPMC-W6000-A3) when connecting an MP940
module to an IO350, or when connecting an IO350 to another IO350.

Be sure to insert the USB terminator (JEPMC-W6020) into the terminal
connector ((1) or (2) in the figure above). See the item on cables for external
appearances and internal connection.

The Mechatrolink conectors 1 and 2 are the same. The terminator may be
inserted into either one.

Insert a USB terminator (JEPMC-W6020) into unused ports.

There is only one channel per Mechatrolink port in the MP940 module. As
shown in the figure above, the top and bottom of the connector are the same
even though it has two receptacles.