Yaskawa MP940 Reference Manual User Manual

Page 397

Advertising
background image

Troubleshooting

MotionSuite™ MP940 Machine Controller Reference Manual

10-44

Note:

indicates ON (“L”) signal; x indicates OFF (“H”) signal

(*1) Occurs in 30W ~ 1000W servo amplifiers.

(*2) Cannot be released by the alarm reset (/ALM-RST) signal. Release by powering off the

device after removing the cause of the alarm.

A.C9

Encoder
Communication Error*2

Communication cannot
be achieved between
the encoder and the
servo motor.

A.CA

Encoder
Parameter Error*2

An encoder parameter is
corrupted.

A.Cb

Encoder
Echoback Error*2

The content of the
encoder communication
is mistaken.

A.d0

Excessive Position
Deviation

The position deviation
pulse exceeds the value
set in user parameter
Pn505.

A.E0

x

No options

No options (MP940)
have been mounted.

A.E1

Option Timeout

No response from the
option port

A.E2

Option WDC Error

There is an error in the
option (MP940) WDC.

A.F1

x

Power Lines Open
Phase

One of the three main
power supply phases is
not connected.

CPF00

Not specified

Digital Operator
Transmission Error

Communication cannot
be established between
the digital operator
(JUSP-0PO2A-2) and
the servo amplifier.

CPF01

A.- -

x

Not an error display

Indicates normal
operation.

Alarm Display and Alarm Code Output Relationship (Continued)

Alarm

Display

Alarm Code Output

ALO1

ALO2

ALO3

Servo
Alarm

(ALM)

Output

Alarm Name

Alarm Content

Advertising