Fixed parameters (continued) – Yaskawa MP940 Reference Manual User Manual

Page 213

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

Parameter Details

6-13

21

Gear Ratio (Motor)

Parameter that sets up gear ratio between the motor and load.
Set up the following 2 values in the configuration so that if
motor axis rotates m rotations, then load axis rotates n rota-
tions.
Gear ratio (motor side) = m
Gear ratio (load side) = n
Setting Example

In the above diagram: Set Decel Ratio = n/m = 3/7~4/9 = 4/21
Then set: Gear Ratio (Motor Side) = 21
Gear Ratio (Load Side) = 4

1

22

Gear Ratio (Load)

1

23

Maximum Value of
Rotary Counter

When a rotary axis is set, set the reset position upon 1 rotation.
This is disabled in the case of linear axes.

Setting range: 1 ~ 2

31-1

(Command Unit)

(Ex.) Reset at each 360 degree in a rotating unit.

360000

27

Forward Software
Limit

Sets the position at which the soft limit function operates.
Setting range: 1 ~ 2

31

-1(Command Unit)

Set up using or not using the soft limit function in b7 and b8 of
Fixed Parameter No. 17 [Motion Controller Function Selection
Flag].

2

31

-1

Fixed Parameters (Continued)

Number

Name

Content

Default

Value

Motor

Axis m

Turns

7 Turns

3 Turns

9 Turns

4 Turns

Load Axis n

Turns

270・‹

180・‹

90・‹

0・‹

0

POSMAX

Advertising