MotionSuite™ MP940 Machine Controller Reference Manual

11-64

See the section on “Zero-Point Return Mode” for details.

Set the zero-point return format by numbers 0 ~ 7 in fixed motion param-
eter 31 “Zero-Point Return Method”.

The details of each method are shown below.

DEC1+C-phase Pulse Format

Executes zero-point return using a limit switch (deceleration LS) and a
zero-point signal (c-phase pulse) after fast feed by linear accel/decel (with
a transition band).

Limit switches are used with the following machine configurations.

Deceleration

LS

Deceleration

LS

0: Disabled

1: Enabled

(B Contact)

(A Contact)

High

Deceleration
LS

Machine Full

Operation Range

Low

Speed

Reference

0

Fast Feed

Speed

Forward Reverse

Zero

Point

Creep Speed

Approach Speed

Dog-leg

(Deceleration LS)

Zero Point Signal

(C-phase pulse)

Time

Zero Point

Return

Position

Zero Return Final Run Distance

1.

2.

3.

4.