Yaskawa MP940 Reference Manual User Manual

Page 259

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

SGDH User Parameters

6-59

Pn001
Function Selection
Application Switch 1
(continued)

1

Motor
stop
method at
overtravel
(0, 1, 2)
(contin-
ued)

Related Parameters
Switching between use/non-use of over-
travel input signals is set by the following
user parameters.
Pn50A.3: Use/non-use of P–OT forward pro-
hibit input signal
Pn50B.0: Use/non-use of N–OT reverse
prohibit input signal.

Sets the stopping torque at overtravel (for-
ward prohibit input, reverse prohibit input).
Pn406: Emergency Stop Torque

0

Speed
Torque
Position

2

AC/DC
power
input
selection
(0, 1)

0: DC power input non-compatibility: Inputs
AC power via terminals L1, L2, (L3).
1: DC power input compatibility: Inputs DC
power via (+) 1 - (-) power input. 1

0

3

Warning
Code
Output
Selection
(0, 1)

Sets the warning content when outputting
alarm codes.
0: ALO1, ALO2, and ALO3 output alarm
codes only.
1: ALO1, ALO2, and ALO3 output both
alarm codes and warning codes. Alarm sig-
nal output remains ON (normal) during
warning code output.
/WARN Signal: Overload, Regen Overload
The warning code is output by the following
three bits:

0

User Parameters (Continued)

User Parameter

Number

Digit

Position

Name

(Setting

Range)

Contents

Default
Setting

Control

Mode

The short wiring in
the figure at left
can be omitted if
P-OT and N-OT
are not used.

CN1-42
(P-OT)

CN1-43
(N-OT)

Servo Amplifier

OV

Warning

Indicator

Warning Code Output Sig-

nal

Meaning

AL01

AL02

AL03

A.91

ON

OFF

OFF

overload

A.92

OFF

ON

OFF

Regenerative

overload

Advertising