MotionSuite™ MP940 Machine Controller Reference Manual

SGDH User Parameters

6-91

Pn50A
(continued)

2

/P-CON
Signal
Mapping

0 ~ F

Set to 8 - disabled

8:disabled

Speed
Torque
Position

3

/P-OT
Signal
Mapping

0 ~ F

Set to 2 - this assigns the /P-OT

signal to SI2 (CN1-2)

2:SI2

Pn50B Input
Signal
Selections 2

0

N-OT
Signal
Mapping

0 ~ F

Set to 3 - this assigns the /P-OT

signal to SI2 (CN1-3)

3:SI3

1

/ALM-RST
Signal
Mapping

0 ~ F

Set to 8 - disabled

8:disabled

2

/P-CL
Signal
Mapping

0 ~ F

Set to 8 - disabled

8:disabled

3

N-CL Signal
Mapping

0 ~ F

Set to 8 - disabled

8:Disabled

Pn50C
Input Signal
Selections 3

0

/SPD-D
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

Speed
Torque
Position

1

/SPD-A
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

2

/SPD-B
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

3

/C-SEL
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

Pn50D
Input Signal
Selections 4

0

/ZCLAMP
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

Speed
Torque
Position

1

/INHIBIT
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

2

/G-SEL
Signal
Mapping

0 ~ F

Set to 8 - disabled

8: disabled

3

Unused

0 ~ F

Set to 8 - disabled

8: disabled

Sequence Related Parameters - Input Signal Selection (Continued)

User

Parameter

Number

Digit

Position

Name

Setting

Range

Content

Default
Setting

Control

Mode