MotionSuite™ MP940 Machine Controller Reference Manual

SGDH User Parameters

6-63

Gain-related Parameters

A detailed list of gain-related parameters appears below.

Gain Related Parameters

User

Parameter

Number

Digital

Position

Name

(setting

range)

Content

Default

Setting

Control

Mode

Pn100
Speed Loop Gain

Hz
1 ~ 2000

This is the parameter that determines the
responsiveness of the speed loop. Set
within a range that does not result in vibra-
tion in the machine system.The higher the
value, the more responsive the system
becomes; however, limits apply in accor-
dance with the function characteristics.

This is the value of the speed loop gain
(Kv) units (Hz) when the user parameter
Pn103 Inertia Ratio is set correctly.
See Pn103 for details on the inertia ratio.

40

Speed
Torque
Position

Speed

Reference

Speed Loop Gain

Speed Feedback

+

-

Kv(1+ )

1

TiS

Advertising