SGDH User Parameters

6-61

Pn002
Function Selection
Application
Switch 2

2

Absolute
Encoder
Usage
Method
(0, 1)

Selects the usage method of the absolute
encoder.
0: The absolute encoder is used as an abso-

lute encoder.

1: The absolute encoder is used as an incre-

mental encoder.

Related Parameters
Pn205: Multi-turn limit setting
Multi-turn limit setting: This is the upper limit
of the multi-turn data. When Pn002.2 = 0,
the multi-turn data varies within the range of
Pn205 (multi-turn limit setting) starting from
0.

0

Speed
Torque
Position

3

Prepara-
tion

0

Pn003
Function Selection
Application
Switch 3

0

Analog
Monitor 1
(0 ~ 7)

The analog monitor signal can be varied by
setting user parameters Pn003.0 and
Pn003.1.
Set the following when using with the
MP940:
Pn003.0: 2 Torque Reference Monitor
Pn003.1: 0 Motor Speed Monitor

2

Speed
Torque
Position

0

1

Analog
Monitor 2
(0 ~ 7)

Cable Color: Signal Name

Content

White

Analog Monitor 1

TorqueReference 1W100%
Rated Torque

Red

Analog Monitor 2

Motor Speed: 1W1000rpm

Black

GND (0V)

2

Unused

0

3

Unused

0

User Parameters (Continued)

User Parameter

Number

Digit

Position

Name

(Setting

Range)

Contents

Default
Setting

Control

Mode

”’

CN5

・•

・•

・Ô

White

CN5

Black

Black

Red