Yaskawa MP940 Reference Manual User Manual

Page 307

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

Starting the Absolute Encoder Function

7-13

Select the absolute encoder usage method by the following user parameter.

Set the following to 0 to enable the absolute encoder.

Set the multi-turn limit into the servo amplifier by the user parameters.

The multi-turn data varies within a range of -32768 ~ +32767 when the
multi-turn limit setting is 65535 (factory setting). In all other settings, the
multi-turn data varies within a range of 0 ~ (value set in Pn205).

When a servomotor rotates in a negative direction from 0, the multi-turn data
varies in the Pn205 setting. When a servomotor rotates in a positive direction
from the Pn205 setting, the multi-turn data changes to 0. Set (m-1) into
Pn205. Recycle the power after modifying user parameters Pn002.2 and
Pn205.

The multi-turn limit value in the encoder is set at delivery to 65535, as in the
servo amplifier. The following alarm is generated if the servo amplifier
power is cycled after modifying the servo amplifier multi-turn limit value in
Pn205.

Alarm Name: Multi-turn Limit Non-coincidence

On = low signal; Off = high signal

Pn002.2

Absolute Encoder Usage Method

Factory Setting
0

Speed Control/Torque
Control/Position Control

Pn002.2 Setting

Content

0

The absolute encoder is used as an absolute encoder.

1

The absolute encoder is used as an incremental encoder.

Pn205

Multi-turn Limit Setting

Unit
rev

Setting Range
0 ~ 65535

Factory Setting
65535

Speed Control/
Torque Control/
Position Control

Alarm Display

Alarm Code Output

Alarm Content

ALO1

ALO2

ALO3

A.CC

On

Off

On

The multi-turn limit values in the encoder
and servo amplifier do not match.

Advertising