background image

MotionSuite™ MP940 Machine Controller Reference Manual

Parameters

A-18

17
(cont)

Servo Axis
Functionality

Bit 8: USE_SLIMN

Enable
Soft Limit (reverse) Selection

0: Enable / 1: Disable

Bit 9: USE_OV

Enable Override Selection

0: Enable / 1: Disable

Bit 10: INV_DEC

Deceleration LS Inversion
Selection

0: Not inverted
1: Inverted

Bit 11: Unused

Bit 12:

Bit 13: OVT1_SEL

Positive Overtravel
Selection

0: Enable / 1: Disable

Bit 14: OVT2_SEL

Negative Overtravel
Selection

0: Enable / 1: Disable

18

Number of Decimal
Places

0~5
(default = 3)

Sets the number of laces
below the decimal point in a
command
(Exp.)
When the Number of Decimal
Places = 3 mm: 1 Command
Unit = 0.001mm deg: 1 Com-
mand Unit = 0.001 deg inch: 1
Command Unit = 0.001 inch

The minimum
command unit is
determined by this
parameter and
command unit
selection (see fixed
servo parameter 17).

19

Command Units per
Revolution

1~2

31

-1

(default = 10000)

1 = 1 command unit

21

Gear Ratio (motor)

1~65535
(default = 1)

1~1 (rotations)

22

Gear Ratio (load)

1~65535
(default = 1)

1~1 (rotations)

23

Maximum Value of
Rotary Counter

1~2

31

-1

(default =360000)

1 = 1 command unit

27

Forward Software
Limit

-2

31

~2

31

-1

(Default = 2

31

-1)

1 = 1 command unit

29

Reverse Software
Limit

-2

31

~2

31

-1

(Default = 2

31

-1)

1 = 1 command unit

31

Home Return Type

0~7
(default = 0)

0: DEC1 Signal + C-pulse

1: ZERO Signal

2: DEC1 Signal + ZERO Signal

3: C-pulse

4: DEC2 Signal + ZERO Signal

5: DEC1 Signal + LMT Signal + ZERO Signal

6: DEC2 Signal + C-pulse

7: DEC1 Signal + LMT Signal + ZERO Signal

Table 7: Fixed Parameters (Continued)

No.

Name

Setting Range

(Bit Name)

Meaning

Note