Absolute Encoder Usage Method

MotionSuite™ MP940 Machine Controller Reference Manual

7-24

Observe the following flowchart as a procedure for saving values to the
buffer.

An example for programming (ladder program) the above flow is depicted
below. The axis used is the first axis of module number 1. Overwrite the
motion parameter register number if the module number and axis number
differ.

High-speed drawing scan

start

Is this the 1st scan after

High-speed scan start?

Zero point setting start?

Toggle Buffer Enabled flag ON

Toggle Buffer Selection flag =

1?

Copy the monitor parameter

value to buffer 1

Toggle Buffer Enabled flag 0

Copy the monitor parameter

value to buffer 0

High-speed drawing scan

end

Toggle Buffer Enabled flag 1