background image

SGDH User Parameters

MotionSuite™ MP940 Machine Controller Reference Manual

6-92

Pn511 Input
Signal
Selections 5

0

/DEC Signal
Mapping

0 ~ F

Set to 1 - this assigns the /DEC

signal to SI1 (CN1-44)

1/Dec

Speed
Torque
Position

1

/EXT 1 Sig-
nal
Mapping

0 ~ F

Set to 4 - this assigns the /EXT1

signal to SI4 (CN1-44)

4:/Ext1

2

/EXT 2 Sig-
nal
Mapping

0 ~ F

Set to 5 - this assigns the /EXT2

signal to SI5 (CN1-45)

5:/Ext2

3

/EXT 3 Sig-
nal
Mapping

0 ~ F

Set to 6 - this assigns the /EXT3

signal to SI6 (CN1-46)

6:/Ext3

Sequence Related Parameters - Input Signal Selection (Continued)

User

Parameter

Number

Digit

Position

Name

Setting

Range

Content

Default
Setting