MotionSuite™ MP940 Machine Controller Reference Manual

Mechatrolink Function

4-35

Mechatrolink Specifications

Mechatrolink Communication Specifications

The Mechatrolink communication specifications in MP940 are shown below.

Master/Slave

The MP940 can be selected for use as a master or slave node. An axample is
given below of master/slave connection.

When the MP940 is used as a master

Connection Example

Number

Item

Specification

1

Transmission Path Status

Bus Type

2

Transmission Path

Electrical Bus

3

Baud Rate

4Mbps

4

Communication Period

1ms/2ms/4ms

5

Number of Nodes Connected

14

6

Transmission Control Format

Cyclic

7

Data Conversion

1:N

8

Transmission Mode

Control transmission

9

Error Control

CRC check, number of expressions check, timer

MP940

SGDH

ST#1

ST#1

ST#1

14 Nodes
Max.

Master Node

Slave Node