Mechatrolink specifications, Master/slave – Yaskawa MP940 Reference Manual User Manual
Page 126

MotionSuite™ MP940 Machine Controller Reference Manual
Mechatrolink Function
4-35
Mechatrolink Specifications
Mechatrolink Communication Specifications
The Mechatrolink communication specifications in MP940 are shown below.
Master/Slave
The MP940 can be selected for use as a master or slave node. An axample is
given below of master/slave connection.
When the MP940 is used as a master
Connection Example
Number
Item
Specification
1
Transmission Path Status
Bus Type
2
Transmission Path
Electrical Bus
3
Baud Rate
4Mbps
4
Communication Period
1ms/2ms/4ms
5
Number of Nodes Connected
14
6
Transmission Control Format
Cyclic
7
Data Conversion
1:N
8
Transmission Mode
Control transmission
9
Error Control
CRC check, number of expressions check, timer
MP940
SGDH
ST#1
ST#1
ST#1
14 Nodes
Max.
Master Node
Slave Node