Position-related constants, Position related parameters – Yaskawa MP940 Reference Manual User Manual

Page 274

Advertising
background image

SGDH User Parameters

MotionSuite™ MP940 Machine Controller Reference Manual

6-74

Position-related Constants

A detailed list of position-related parameters appears below.

Position Related Parameters

User

Parameter

Number

Digit

Position

Name

(setting

range)

Content

Default

Setting

Control

Mode

Pn200
Position
Control
Reference
Selection
Switches *3

0

Command
Pulse
Form

Cannot be used in connection with an
MP940.

0

Position

1

CLEAR
Signal
Form

Cannot be used in connection with an
MP940.

2

CLEAR
Operation

Cannot be used in connection with an
MP940.

3

Filter
Selection

Cannot be used in connection with an
MP940.

Pn201

PG Divider Ratio

*3

p/r
16 ~ 16384

Cannot be used in connection with an
MP940

16384

Speed
Torque
Position

Pn202
Electronic Gearing

Ratio (Numerator)

∗3

1 ~ 65535

Cannot be used in connection with an
MP940.

4

Position

Pn203
Electronic Gearing

Ratio (denominator)

∗3

1 ~ 65535

Cannot be used in connection with an
MP940.

1

Position

Pn204
Position Reference
Accel/Decel Time
Constant

0.01ms
0 ~ 6400

Cannot be used in connection with an
MP940.

0

Position