The following table details the meaning of each parameter, and the difference between
use/non-use.

Fixed Parameters

These parameters are normally not changed after being set, insofar as the
machine configuration/specifications do not change. Set these in the
MotionWorks™ Fixed Parameter Setting screen.

Table 7: Fixed Parameters

No.

Name

Setting Range

(Bit Name)

Meaning

Note

1

Axis Enabled

0 or 1
(default = 6)

0: Non-use selection
1: Use selection

13

Latch Input Signal
Type

0 or 1
(default = 0)

0: DI input signal
1: C-pulse input signal

14

Functions

Bit 0~1: Unused

Bit 2: LIMITSEL

Limit Switch Signal
Selection

0: OBC001F use
1: DI Signal Use

Bit 3~6: Unused

Bit 7: MCMDSEL

Motion Command Use
Selection

0: Unused / 1: Used

Bit 8~15: Unused

15

Unused

16

Simulation Mode

0~2
(default =0)

0: Normal Run Mode

1: Simulation Mode

17

Servo Axis
Functionality

Bit 0~3: 0~7
CMD_UNIT

Command Unit Selection

0: pulse (electronic
gearing disabled)

1: mm

2: deg

3: inch

Bit 4: USE_GEAR

Electronic Gearing Selection

0: Enable / 1: Disable

Bit 5: PMOD_SEL

Axis Selection

0: Limited-length
Axis
1: Infinite-length Axis

Bit 6: USE_BKRSH

Enable Backlash Compensa-
tion Selection

0: Enable / 1: Disable

Bit 7: USE_SLIMP

Enable Soft Limit (forward
Selection

0: Enable / 1: Disable

Advertising