MotionSuite™ MP940 Machine Controller Reference Manual

Parameter Details

6-25

Other Command/Mode Settings

Number

Name

Register

Number

Bit Name

Content

Default

Value

3

Forward Torque
Limit

OWC002

-32768~32767 Sets the torque limit referenced to a servo

amplifier, or inverter.
Unit:0.01%
Set to a positive value (units of 0.01%) for
VS-866, and a negative value (units of
0.01%) for servo amplifiers.

-300.00
(-300.00%)

4

Unused

OWC003

Set 0

0

5

Forward Speed
Limit

OWC004

0 ~ 32767

Sets forward and reverse speed limits.
Designated in percentage (%) of rated
speed.
The limit is output if the result if the result
of adding the compensation speed to the
designated speed exceeds the limit.

150.00
(150.00%)

6

Reverse Speed
Limit

OWC005

0 ~ 32767

150.00
(150.00%)

7

Zero-point
Offset

OLC006

-2

31

~ 2

31-1

It is possible to offset the position data by
the setting value of this register only.
Although this is also enabled during RUN,
use this during OFF.
This register OLC006 is data which struc-
tures the position control managed by the
MP940 module.Erroneous settings in this
register affect the following motion opera-
tions.Always be sure to check that the data
settings are correct prior to operation.
Failure to conduct these checks may result
in tool damage, and physical injury, due to
the intervention of the tool.

0

8 ~ 10

Unused

OLC008

Set 0

0

Output

Speed

Positive Speed

Limit

Negative Speed

Limit