A detailed list of sequence-related parameters appears below.

Sequence Related Parameters - Output Signal Selection

User

Parameter

Number

Digit

Position

Name

Setting

Range

Content

Default

Settings

Control Mode

Pn50E Output
Signal
Selections 1

0

Positioning
Completion
Signal Map-
ping

0

1

2

3

Disabled (Do not use the

signal output on the left.)

Output the signal on the left

using output terminal SO1
(Cn1-25, 26),

Outputs the signal on the left

using output terminal SO2
(CN1-27, 28),

Outputs the signal on the left

using output terminal SO3
(CN1-29, 30).

1:SO1

Speed Torque
Position

1

Speed Coin-
cidence
Detection
Signal
Mapping
(/V-CMP)

0 ~ 3

As above

1:SO1

2

Run Detec-
tion Signal
Mapping
(/TGON)

0 ~ 3

As above

2:SO3

3

Servo
Ready Sig-
nal Mapping
(/S-RDY)

0 ~ 3

As above

3:SO3

Pn50F Output
Signal
Selections 2

0

Torque Limit
Detection
Signal
Mapping
(/CLT)

0 ~ 3

As above

0:Unused Speed Torque

Position

1

Speed Con-
trol Signal
Mapping

)

0 ~ 3

As above

0:Unused

2

Brake Inter-
lock Signal
Mapping
(/BK)

0 ~ 3

As above

0:Unused