Output signal selection – Yaskawa MP940 Reference Manual User Manual
Page 293

MotionSuite™ MP940 Machine Controller Reference Manual
SGDH User Parameters
6-93
Output Signal Selection
A detailed list of sequence-related parameters appears below.
Sequence Related Parameters - Output Signal Selection
User
Parameter
Number
Digit
Position
Name
Setting
Range
Content
Default
Settings
Control Mode
Pn50E Output
Signal
Selections 1
0
Positioning
Completion
Signal Map-
ping
0
1
2
3
Disabled (Do not use the
signal output on the left.)
Output the signal on the left
using output terminal SO1
(Cn1-25, 26),
Outputs the signal on the left
using output terminal SO2
(CN1-27, 28),
Outputs the signal on the left
using output terminal SO3
(CN1-29, 30).
1:SO1
Speed Torque
Position
1
Speed Coin-
cidence
Detection
Signal
Mapping
(/V-CMP)
0 ~ 3
As above
1:SO1
2
Run Detec-
tion Signal
Mapping
(/TGON)
0 ~ 3
As above
2:SO3
3
Servo
Ready Sig-
nal Mapping
(/S-RDY)
0 ~ 3
As above
3:SO3
Pn50F Output
Signal
Selections 2
0
Torque Limit
Detection
Signal
Mapping
(/CLT)
0 ~ 3
As above
0:Unused Speed Torque
Position
1
Speed Con-
trol Signal
Mapping
)
0 ~ 3
As above
0:Unused
2
Brake Inter-
lock Signal
Mapping
(/BK)
0 ~ 3
As above
0:Unused