System Errors

MotionSuite™ MP940 Machine Controller Reference Manual

9-20

Interrupt Status

Interrupt Module Details

Note:

Model = 01H~05H:Reserved by System

mm = 06H:MP940/LIO is fixed at 6
mm = 07H:MP940/Counter (PI) is 07H

Slot

ss = slot number of interrupt module
MP940/LIO is in slot 3, and thus 03H
MP940/Counter is in slot 5, and thus 05H

Cause of Interrupt

xxxx = DI interrupt of the MP940/LIO is fixed at 1CH
The interrupt of the MP940/Counter is also fixed at 1CH

System Operation Error Code Status - 2

Error

Code

Error Content

System Default

Integer
Operation

0001H

Integer operation - underflow

-32768

0002H

Integer operation - overflow

+32767

0003H

Integer Operation - Division Error

0

Name

Register

Number

Reference

Interrupt Detection Count

SW00698

Number of Interrupts

Module in which interrupt occurred

SW00699

Number of Modules with 1 Interrupt

Interrupt Module

SW00700

Interrupt Module 1

SW00701

SW00702

Reserved for System

SW00703

SW00798

Reserved for System

SW00799

15

8

7

0

SW00700

Module *1

Slot *2

mmssH

SW00701

Status *3

xxxxH