MP940 Module Battery

MotionSuite™ MP940 Machine Controller Reference Manual

8-4

Preparation for Battery Replacement

Prepare the replacement battery (Model: BA000518). This battery is not
commercially available; it must be ordered from Yaskawa. The appearence of
the replacement battery is shown in the figure below.

BA000518 (battery w/ cables)

Battery Change Procedure

Change the battery as follows:

1. Check that the “POWER” display light on the MP940 module is ON.

2. Remove the ends of the connectors attached to the battery leads from

the MP940 module connectors, and remove the internal battery from
the battery holder.

3. Firmly insert the connectors attached to the ends of the replacement

battery leads into the MP940 module connectors. Then place the
replacement battery into the battery holder.

4. Check that the “BAT” display light on the MP940 module is OFF.

Battery replacement is now complete.

Be sure to feed power to the MP940 module during battery replacement.
Cutting off the power to the MP940 module while replacing the battery risks
loss of the programs and data stored in the module memory.