MotionSuite™ MP940 Machine Controller Reference Manual

SGDH User Parameters

6-75

Pn205
Multi-turn

Limit Setting

∗3

rev
0 ~ 65535

In systems where an absolute encoder is
desired, such as circular tables, etc., it is
more convenient to return the multi-turn
data from the encoder to 0 every m rota-
tions in machines where the motors
rotate m times when the additional axes
rotate n times.
The multi-turn data varies within a range
of -32768 ~ +32767 when the multi-turn
limit setting is 65535 (factory setting).
When a servomotor rotates in a negative
direction from 0, the multi-turn data var-
ies in the Pn205 setting.When a servo-
motor rotates in a positive direction from
the Pn205 setting, the multi-turn data
changes to 0.Set (m-1) into Pn205.
Note: Recycle power after modifying user
parameters Pn001.0 and Pn205.
Related Parameters
The multi-turn limit setting is enabled
when Pn002.2 Absoute Encoder Usage
Method is set to 0.
0: The absolute encoder is used as an

absolute encoder.

1: The absolute encoder is used as an

incremental encoder.

65535

Speed
Torque
Position

Pn206
Reserved Constant

p/rev
5/3 ~
32768

Cannot be used in connection with an
MP940.

16384

Position

Pn207
Position
Control
Function
Switches *3

0

Position
Reference
Filter
Selection

Cannot be used in connection with an
MP940.

0

Position

1

Position
Reference
Option

2

Unused

3

Unused

Pn208
Position Reference
Movement Averaging
Time

Cannot be used in connection with an
MP940.

0

Position

Position Related Parameters (Continued)

User

Parameter

Number

Digit

Position

Name

(setting

range)

Content

Default

Setting

Control

Mode