Other command/mode settings (continued) – Yaskawa MP940 Reference Manual User Manual

Page 237

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

Parameter Details

6-37

41

STEP Distance OLC028

0 ~ 2

31-1

Sets the amount of motion in motion command
(OWC020) stepping feed in command units.

Unit: Command Unit

0

43

Home Offset

OLC02A

-2

31

~ 2

31-1

When the motion command (OWC020) is
Zero-point Return (ZRET), the axis moves
for a set distance after detection of an
enabled zero-return pulse, and then
stops. This position is the machine coor-
dinate zero point.
Unit: Command Unit

0

45

Speed Override OWC02C 0 ~ 32767

Override sets the output ratio with regard
to the feed speed (OWC022) setting in
outs of 0.01%.

10000

Enabled when the override selection of fixed parameter No. 17 (Bit 9 of motion controller
function selection flag) is enabled.

Other Command/Mode Settings (Continued)

Number

Name

Register

Number

Setting Range

Content

Default

Value

Speed

Reference

0

Fast Feed Speed

Reverse Forward

Zero

Point

Creep Speed

Approach

Speed

Dog-Leg

(deceleration LS)

Zero Point Signal

(C-phase pulse)

Time

Zero Point

Return

Position

Zero Point Return Final

Run Distance

1.

2.

3.

4.

Fast Feed Speed Output

Reference Speed × Override = Output Speed

(OLxx22)

Reference

Speed

(OLxx22)

Override

Override Function

Selection

Fixed Parameter b9

100%

E

n

able

d

Output

Speed

(OWxx2C)

(OWxx2C)

Di
sa
bl

ed

Advertising