MotionSuite™ MP940 Machine Controller Reference Manual

Parameters

A-20

Motion Setup Parameters

The setup parameters are used as commands to the motion module. They
are transferred as a group to the motion module at the start of high-speed
scanning. Motion control can be executed simply by setting the
parameters into this register area.

Table 8: Setup Parameters

No.

Name

Register

Number

Setting Range

(Bit Name)

Meaning

1

Run Mode

OWC000

Bit 0: NCON

Speed Reference Output Mode

Bit 1: TCON

Torque Reference Output Mode

Bit 2: PCON

Position Control Mode

Bit 3: PHCON

Phase Control Mode

Bit 4: ZRN

Zero-point Return Mode*

Bit 5: PHTEST

Phase Control Test Signal

Bit 6: ACR

Alarm Clear

Bit 7: PHREFOFF

Disable Phase Reference Generation
Operation

Bit 8: MCDSEL

0: Motion Command Code (OWC020)
disabled
1: Motion Command Code (OWC020)
enabled

Bit 9: ZRNDIR

Zero Point Return Direction
0: Negative (decreasing)
1: Positive (increasing)

Bit 10: ABSRD

Absolute Position Readout Request

Bits 11~12:

Unused

Bit 13: DIINTREQ

DI Latch Detection Request

Bit 14:

Unused

Bit 15: IRESET

Phase Control Integral Reset