Motion setup parameters, Table 8: setup parameters – Yaskawa MP940 Reference Manual User Manual
Page 507

MotionSuite™ MP940 Machine Controller Reference Manual
Parameters
A-20
Motion Setup Parameters
The setup parameters are used as commands to the motion module. They
are transferred as a group to the motion module at the start of high-speed
scanning. Motion control can be executed simply by setting the
parameters into this register area.
Table 8: Setup Parameters
No.
Name
Register
Number
Setting Range
(Bit Name)
Meaning
1
Run Mode
OWC000
Bit 0: NCON
Speed Reference Output Mode
Bit 1: TCON
Torque Reference Output Mode
Bit 2: PCON
Position Control Mode
Bit 3: PHCON
Phase Control Mode
Bit 4: ZRN
Zero-point Return Mode*
Bit 5: PHTEST
Phase Control Test Signal
Bit 6: ACR
Alarm Clear
Bit 7: PHREFOFF
Disable Phase Reference Generation
Operation
Bit 8: MCDSEL
0: Motion Command Code (OWC020)
disabled
1: Motion Command Code (OWC020)
enabled
Bit 9: ZRNDIR
Zero Point Return Direction
0: Negative (decreasing)
1: Positive (increasing)
Bit 10: ABSRD
Absolute Position Readout Request
Bits 11~12:
Unused
Bit 13: DIINTREQ
DI Latch Detection Request
Bit 14:
Unused
Bit 15: IRESET
Phase Control Integral Reset